Huawei NetEngine AR720
Forwarding performance: 9 Mpps to 25 Mpps | Number of connected terminals: 700 | Fixed WAN ports: 2 x GE combo ports | Fixed LAN ports: 8 x GE ports (can be switched to WAN ports) | Dimensions (H x W x D): 43.6 mm x 442 mm x 220 mm
Specifications:
Remarks | When configuring cards, ensure that the total power of the configured cards does not exceed 37 W or contact technical support engineers to obtain more suggestions. The routers manufactured after March 31, 2023 support only V300R022C10 and later versions. |
Installation type | Rack,Work bench,Against the wall |
Dimensions without packaging (H x W x D) | – Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 220.4 mm (1.75 in. x 17.41 in. x 8.68 in.) – Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 225.2 mm (1.75 in. x 17.41 in. x 8.87 in.) |
Dimensions with packaging (H x W x D) | 90 mm x 390 mm x 570 mm (3.54 in. x 15.35 in. x 22.44 in.) |
Weight with packaging | 4.6 (10.12) |
Weight without packaging | 3.2 (7.04) |
CPU | 1.4 GHz, 4 Cores |
Memory | 4 GB |
Console port | RJ45 |
RTC | Supported |
Maximum power consumption | 33 |
Power supply mode | AC built-in |
Number of power modules | 1 |
Rated input voltage | 100 V to 240 V, 50 Hz/60 Hz |
Input voltage range | 90 V to 264 V, 47 Hz to 63 Hz |
Maximum input current | 2 |
Maximum output power | 70 |
Safety regulation certification | IEC/EN/UL60950-1 IEC/EN/UL62368-1 GB 4943.1 |
EMC certification | EN 55032 EN 55035 CISPR 32 GB 9254 EN 55024 CISPR 24 GB/T 17618 EN 300 386 VCCI-CISPR 32 AS/NZS CISPR32 IEC 61000-3-2/EN 61000-3-2 IEC 61000-3-3/EN 61000-3-3 |
Type of fans | Built-in |
Number of fan modules | 0 |
Heat dissipation mode | Air cooling |
Airflow direction | Left to right |
Extended slots (standard configuration) | 2 x SIC |
Number of service board slots | 2 |
Redundant power supply | Not supported |
RPS input | Not supported |
PoE | Not supported |
Noise at normal temperature (acoustic power) | 52.3 dB(A) |
Long-term operating temperature | 0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800 m-5000 m (5906 ft.-16404.2 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity | 5% to 95%, noncondensing |
Long-term operating altitude | < 5000 m (16404.2 ft.) |
MTBF | 30.05 |
MTTR | 2 |
Availability | 0.999992401 |
Đánh giá