Huawei S310-24T4S CloudEngine Switch: 24*10/100/1000BASE-T ports, 4*GE SFP ports, AC power

  • 24*GE Copper, 4*GE SFP
  • Switching Capacity: 260Gbps
  • Forwarding Performance: 42Mpps

Giá bán: Liên hệ báo giá

Tư vấn đặt hàng Để lại thông tin tư vấn

Huawei S310-24T4S CloudEngine Switch

Overview

Table 4-23 Basic information about the S310-24T4S

Item Details
Description S310-24T4S(24*10/100/1000BASE-T ports, 4*GE SFP ports, AC power)
Part Number 98012202
Model S310-24T4S
First supported version V600R022C10

Components

Figure 4-8 S310-24T4S appearance

1

One MODE button

NOTE:

This button is reserved and is not required currently.

2

Twenty-four 10/100/1000BASE-T ports

3

Four 1000BASE-X ports

4

One console port

5

One PNP button

NOTICE:

To restore the factory settings and reset the switch, hold down the button for at least 6 seconds.

To reset the switch, press the button.

Resetting the switch will cause service interruption. Exercise caution when you press the PNP button.

6

Ground screw

NOTE:

It is used with a ground cable.

7

Jack for AC power cable locking strap

NOTE:

The AC power cable locking strap is not delivered with the switch.

8

AC socket

NOTE:

It is used with an AC power cable.

Ports

Table 4-24 Ports on the S310-24T4S

Port Connector Type Description Available Components
10/100/1000BASE-T port RJ45 A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s.

Ethernet cable

1000BASE-X port SFP A 1000BASE-X port can send and receive data at 1000 Mbit/s.
Console port RJ45 The console port is connected to a console for on-site configuration.

Console cable

Indicators and Buttons

The S310-24T4S has similar indicators to those on the S310-24P4S except that the S310-24T4S does not have a PoE mode indicator. For details, see the S310-24P4S.

Power Supply System

The switch has a built-in AC power module and does not support pluggable power modules.

Heat Dissipation System

The switch has a built-in fan for forced air cooling. Air flows in from the left side and front panel, and exhausts from the right side.

When working properly at a normal temperature, the device meets the desktop-class noise requirements. However, the fan speed may be high and the noise may be loud during device startup.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-25 Technical specifications of the S310-24T4S

Item Specification
Dimensions without packaging (H x W x D) [mm(in.)]

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.)

Dimensions with packaging (H x W x D) [mm(in.)] 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.)
Chassis height [U] 1 U
Weight without packaging [kg(lb)] 2.32 kg (5.11 lb)
Weight with packaging [kg(lb)] 3.44 kg (7.58 lb)
Typical power consumption [W] 26.37 W
Typical heat dissipation [BTU/hour] 89.98 BTU/hour
Maximum power consumption [W] 34.04 W
Maximum heat dissipation [BTU/hour] 116.15 BTU/hour
Static power consumption [W] 19.003 W
MTBF [year] 70.75 year
MTTR [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 47 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 35 dB(A)
Number of card slots 0
Number of power slots 0
Number of fans modules 1
Redundant power supply Not supported
Long-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Restriction on the operating temperature variation rate [°C(°F)]

When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Devices cannot start when the temperature is lower than 0°C (32°F).

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)
Long-term operating relative humidity [RH] 5% RH to 95% RH (non-condensing)
Long-term operating altitude [m(ft.)] 0–5000 m (0–16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode AC built-in
Rated input voltage [V] AC input: 100–240 V AC; 50/60 Hz
Input voltage range [V] AC input: 90–290 V AC; 45–65 Hz
Maximum input current [A] 0.8 A
Memory 2 GB
Flash memory 1 GB in total. To view the available flash memory size, run the display version command.
Console port RJ45
Eth Management port Not supported
USB Not supported
RTC Not supported
RPS input Not supported
Service port surge protection [kV] Common mode: ±7 kV
Power supply surge protection [kV] Differential mode: ±6 kV; common mode: ±6 kV
Types of fans Built-in
Heat dissipation mode Air cooling for heat dissipation, intelligent fan speed adjustment
Airflow direction Air intake from left and front, air exhaustion from right
PoE Not supported
Certification

EMC certification

Safety certification

Manufacturing certification

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “Huawei S310-24T4S CloudEngine Switch”